{"collectionById":{"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde":{"id":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","name":"Blog Articles","fieldSchemas":[{"id":"b2aaf651-c4d2-4b30-9281-ec362300d42b","name":"Image de fond","type":"image"},{"id":"3084d9ba-ab55-4e5a-931b-b9db3d09105f","name":"Article Content 1","type":"rich_text"},{"id":"0b77f83b-c31a-4889-b9b3-9a6d2e41fc86","name":"Author Bio","type":"rich_text"},{"id":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4","name":"Slug","type":"slug","role":"slug"},{"id":"df1c88d1-4bd8-4ecd-9059-463b9589de92","name":"Author Name","type":"plain_text"},{"id":"1f58afa6-2748-4188-b4a4-f1e54e37eca9","name":"Image 1","type":"image"},{"id":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383","name":"Title","type":"plain_text","role":"primary"},{"id":"8012fca9-4dbe-4d7c-993c-d37b30a37c6d","name":"Article Content 3","type":"rich_text"},{"id":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3","name":"Fav-image","type":"image"},{"id":"cc1e5ce2-ba49-43af-b78b-225562b85284","name":"Questions fréquentes","type":"rich_text"},{"id":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9","name":"Tag","type":"plain_text"},{"id":"b5be4125-5bdd-482f-8b12-191c8a4422f3","name":"À retenir","type":"rich_text"},{"id":"7b900d5c-96dc-41e2-be74-2a6610216543","name":"Date de publication","type":"plain_text"},{"id":"bc08dd34-58e3-4208-ad8c-a02df2239e1b","name":"Chapô","type":"rich_text"},{"id":"0a981f8a-7dbb-440d-a940-25d9060c9b11","name":"Author Job Title","type":"plain_text"},{"id":"054b5e89-1958-4bbe-907f-bda21bcc691d","name":"Article Content 2 / image","type":"rich_text"},{"id":"7b1ea3d0-62d9-49a8-b96e-f453f816f81e","name":"Article Content 4 / image","type":"rich_text"},{"id":"3885fcba-a6df-473a-8e7e-799777173a06","name":"Image 2","type":"image"}],"itemById":{"7c10a08b-d604-4d4d-a009-2400c53b6b59":{"id":"7c10a08b-d604-4d4d-a009-2400c53b6b59","index":"!","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"dd952d8e-1d3e-4757-8463-a2a82ac18568","value":"{\"image\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"imageThumbnail\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"originalImageHeight\":240,\"originalImageWidth\":375,\"altText\":\"Kit de révision de pièce à main Storz Medical\",\"fileName\":\"image 19.png\"}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"1f58afa6-2748-4188-b4a4-f1e54e37eca9"},{"id":"6918a194-ccf5-446a-9696-7ee76169ba54","value":"Guide pratique","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"0256a557-6df8-4761-989f-998f57f83be5","value":"David Francisque","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"e0d64bb3-571b-4ca4-bd28-ee39b6ed44a2","value":"Dirigeant de S-Médical Conseil","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"0a981f8a-7dbb-440d-a940-25d9060c9b11"},{"id":"e4cf3c21-e9a1-4df0-8d5b-952da2348d02","value":"{\"root\":{\"children\":[{\"children\":[],\"direction\":\"ltr\",\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":\"ltr\",\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"0b77f83b-c31a-4889-b9b3-9a6d2e41fc86"},{"id":"5d062c1f-763e-47af-9948-14953423dc45","value":"{\"image\":\"233ac9873d2651a90309a3e2def59dbe59b8736a\",\"imageThumbnail\":\"233ac9873d2651a90309a3e2def59dbe59b8736a\",\"originalImageHeight\":320,\"originalImageWidth\":768,\"altText\":\"Cabinet médical avec machine par onde de choc\",\"fileName\":\"Frame.png\"}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"b2aaf651-c4d2-4b30-9281-ec362300d42b"},{"id":"5325ca9f-ad00-44f6-a819-fbdb13df3aca","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Un appareil d'ondes de choc radiales s'entretient avant tout par un geste simple : réviser la pièce à main environ tous les 1 million de chocs. C'est aussi une obligation légale pour tout praticien qui l'utilise, cabinet libéral compris. Voici ce qu'il faut savoir pour garder votre appareil fiable et disponible.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"bc08dd34-58e3-4208-ad8c-a02df2239e1b"},{"id":"ceea47ab-01b9-474b-8e4a-ff959851412c","value":"Maintenance et SAV d’un appareil onde de choc : le guide","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"589589f2-6968-4413-9855-8e124d5c36e5","value":"maintenance-appareil-onde-de-choc","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"bc7629a3-71ab-4f19-93b5-cd4cb9460392","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"La maintenance est-elle obligatoire ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Oui. Votre appareil est un dispositif médical, et le Code de la santé publique (art. R.5212-25) impose à tout exploitant d'en assurer la maintenance, \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"y compris en cabinet libéral\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\". Elle peut être réalisée par le fabricant, par un prestataire de tierce maintenance ou par vous-même. Chaque intervention doit être notée dans un \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"registre\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : qui, quand, quoi, et le résultat.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":\"ltr\",\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"3084d9ba-ab55-4e5a-931b-b9db3d09105f"},{"id":"b05914bd-33d2-428a-8955-552f5d5ba317","value":"{\"root\":{\"children\":[{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Révision de la pièce à main : environ tous les \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"1 million de chocs\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\".\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Kit de révision (projectile, tube de guidage, joints) : \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"340 € TTC\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\".\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Maintenance et registre des interventions \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"obligatoires\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" (art. R.5212-25 CSP).\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Devis SAV sous \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"48 h.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":4}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"b5be4125-5bdd-482f-8b12-191c8a4422f3"},{"id":"fd9e9347-d916-49b9-a9df-655f938c95fb","value":"{\"image\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"imageThumbnail\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"originalImageHeight\":240,\"originalImageWidth\":375,\"altText\":\"Photo d'un kit de révision\",\"fileName\":\"image 19.png\"}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"e209398f-8921-4b09-b525-4ca98ae368f5","value":"23 septembre 2026","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"},{"id":"65206430-f8ae-43da-a583-c165b04d06d1","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quelles pièces s'usent ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Dans un appareil radial, un \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"projectile\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" (la masselotte) propulsé par air comprimé percute le \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"transmetteur\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" des milliers de fois par séance. Ce choc répété use trois pièces : le projectile, le tube de guidage et les joints, réunies dans le kit de révision.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand réviser la pièce à main ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noreferrer\",\"target\":null,\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/revision-piece-a-main-onde-de-choc\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Le repère est \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"environ 1 million de chocs\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", lisible sur le compteur de l'appareil. Révisez plus tôt si vous constatez :\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"une \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"baisse de puissance\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" à réglages identiques ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"un \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"bruit de percussion\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" anormal ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"une \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"fuite d'air\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"un \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"échauffement\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" de la pièce à main.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":4}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"listType\":\"number\",\"start\":1,\"tag\":\"ol\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"054b5e89-1958-4bbe-907f-bda21bcc691d"},{"id":"cc7d8c06-67da-4e88-9dde-f423c1d58f07","value":"{\"image\":\"57c060ac92d9645203ccab31017b81649e29c427\",\"imageThumbnail\":\"57c060ac92d9645203ccab31017b81649e29c427\",\"originalImageHeight\":220,\"originalImageWidth\":406,\"altText\":\"\",\"fileName\":\"card-image.png\"}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"3885fcba-a6df-473a-8e7e-799777173a06"},{"id":"1bf77346-b568-46fa-91d2-602552cc5bdb","value":"{\"root\":{\"children\":[{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quel kit de révision commander ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noreferrer\",\"target\":null,\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/kit-revision-storz-medical\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Le kit existe en version Falcon (courte) ou longue, selon que votre pièce à main date d’avant ou d’après 2016. Chez S-Médical Conseil, il est proposé à \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"340 € TTC\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", livré en 2 à 3 jours. En cas de doute sur la référence, envoyez-nous une photo de votre pièce à main.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"7b1ea3d0-62d9-49a8-b96e-f453f816f81e"},{"id":"02d4cfff-0105-4a5d-b889-c8239164cd59","value":"{\"root\":{\"children\":[{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Et en cas de panne ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noreferrer\",\"target\":\"_blank\",\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/panne-appareil-onde-de-choc\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Si la révision ne suffit pas, ou si l'appareil affiche une erreur, \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"n'ouvrez ni l'unité de contrôle ni le compresseur\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\". \",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"S-Médical Conseil, spécialiste du SAV des appareils onde de choc Storz Medical en France, prend le relais :\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Demande\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" via \",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Devis Express\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"internal-link\",\"version\":1,\"textFormat\":1,\"nodeId\":\"2:6135\",\"cmsTarget\":null},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" ou par téléphone.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Diagnostic\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" et devis sous \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"48 h\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Réparation en 7 jours environ\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", transport aller-retour inclus.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Retour\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" avec rapport d'intervention pour votre registre.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":4}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"textFormat\":1,\"listType\":\"number\",\"start\":1,\"tag\":\"ol\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"8012fca9-4dbe-4d7c-993c-d37b30a37c6d"},{"id":"c504a342-1f87-49e3-9152-4450875998c9","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":8,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Questions fréquentes\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"center\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"textFormat\":8,\"tag\":\"h2\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Qui peut assurer la maintenance d’un appareil à ondes de choc ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Le Code de la santé publique (art. R.5212-25) l’autorise au fabricant, à un prestataire de tierce maintenance ou à l’exploitant lui-même. Quel que soit l’intervenant, chaque opération doit être notée dans le registre de maintenance. \",\"type\":\"text\",\"version\":1},{\"type\":\"linebreak\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"La société S Médical Conseil prend en charge l’ensemble des frais d’expédition en France \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"pour rapatrier votre matériel au sein du pôle technique STORZ MEDICAL France, société disposant des agréments nécessaires à la réparation de votre matériel STORZ MEDICAL.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Que doit contenir le registre de maintenance ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Pour chaque intervention : qui l’a réalisée, à quelle date, la nature de l’opération et son résultat. Notez aussi la valeur du compteur de chocs à chaque révision, pour savoir quand prévoir la suivante.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Combien coûte l’entretien courant d’un appareil à ondes de choc ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Le poste principal est le\",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" kit de révision de la pièce à main\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noreferrer\",\"target\":null,\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/kit-revision-storz-medical\"},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : 340 € TTC, à remplacer environ tous les 1 million de chocs, soit tous les 4 mois à 2 ans selon votre activité. En cas de panne, S-Médical Conseil établit un diagnostic et un devis sous 48 h.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"cc1e5ce2-ba49-43af-b78b-225562b85284"}]},"8e0217f5-7cdc-41f6-9db8-474dea263b83":{"id":"8e0217f5-7cdc-41f6-9db8-474dea263b83","index":"!O","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"fc81924b-1d3a-4dc8-9af8-d86e5de1f37f","value":"revision-piece-a-main-onde-de-choc","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"a6dc4f1c-71c5-4cd8-bfc5-e43857c2ca28","value":"Quand réviser la pièce à main d’un appareil onde de choc ?","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"c8c5b9fe-d69c-46a9-9bd6-ef89a18790b1","value":"David Francisque","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"bc5903f5-34d0-47a7-8937-03422d79e1c7","value":"Guide pratique","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"c5c84e77-acfd-4265-bfc0-955de5ec65e5","value":"{\"image\":\"5a6a7af39c577eb6cab53537d23bdca6b652c500\",\"imageThumbnail\":\"08fd98696723a3ddf925504168ddf4eacbee85c1\",\"originalImageHeight\":630,\"originalImageWidth\":1200,\"altText\":\"Nombre de choc possible sur un appareil médical par onde de choc\",\"fileName\":\"fav-quand-reviser-1200x630.png\"}","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"3c7927e3-e5b4-4037-9d32-4f6ec13b2d9f","value":"23 septembre 2026","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"}]},"96831a50-8ca8-4cca-bb18-8954cc156fb7":{"id":"96831a50-8ca8-4cca-bb18-8954cc156fb7","index":"!7","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"f280f385-0249-43c4-9bae-0f98efef4202","value":"Kit de révision Storz Medical : contenu, versions et montage","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"adf99d24-6e9e-4faf-84b7-05693a0dad50","value":"kit-revision-storz-medical","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"1730240e-1f3e-49c2-b3df-87a58b3f8c46","value":"David Francisque","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"152c803c-67cf-41bb-b0ba-5a91befa56b7","value":"23 septembre 2026","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"},{"id":"682524d3-f207-4b3a-9114-d267b2365633","value":"{\"image\":\"413c90202eefbf53f8adc18b78726fd4025e75e1\",\"imageThumbnail\":\"3c5de459399cc5edb94930127750757a6ebe2a29\",\"originalImageHeight\":1500,\"originalImageWidth\":1500,\"altText\":\"Kit de révision Storz Medical avec le projectile, le tube de guidage et les joints. \",\"fileName\":\"Kit de révision Storz medical.jpg\"}","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"4fcf599e-5537-4c9d-bee9-ae113f3be715","value":"Guide pratique","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"}]},"e678315e-a26e-4261-99f6-2576fbb7bc4e":{"id":"e678315e-a26e-4261-99f6-2576fbb7bc4e","index":"!f","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"7adb5007-d326-409e-9fb4-04482e88f680","value":"panne-appareil-onde-de-choc","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"578a76f6-f5fb-4576-be11-06947a662dc3","value":"Panne d'appareil onde de choc : causes et solutions","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"c871064a-a8f9-4dc4-b0d7-e684f2e84164","value":"Guide pratique","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"94e4d304-ded3-4c95-859f-57037f4a5d99","value":"David Francisque","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"927993f4-8665-45ad-bf18-758cb09649bd","value":"29 octobre 2026","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"},{"id":"8516ec14-0ad4-4278-a332-4f13425464ee","value":"{\"image\":\"f824fa3992d12744707ba8b44c5f74dfe00227ec\",\"imageThumbnail\":\"0950d780438ba7acb4e531b12cd4a646f27d4890\",\"originalImageHeight\":1254,\"originalImageWidth\":1254,\"altText\":\"Inspection des traces d’usure sur l’embout métallique d’un applicateur d’ondes de choc.\",\"fileName\":\"Inspection de l’embout métallique radial\"}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"}]}}}},"slugByItemId":{"8e0217f5-7cdc-41f6-9db8-474dea263b83":"revision-piece-a-main-onde-de-choc","96831a50-8ca8-4cca-bb18-8954cc156fb7":"kit-revision-storz-medical","12124197-c3d3-4112-b64a-fee99a5f3c36":"onde-de-choc-radiale-ou-focale","7c10a08b-d604-4d4d-a009-2400c53b6b59":"maintenance-appareil-onde-de-choc","e678315e-a26e-4261-99f6-2576fbb7bc4e":"panne-appareil-onde-de-choc"}}