{"collectionById":{"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde":{"id":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","name":"Blog Articles","fieldSchemas":[{"id":"b2aaf651-c4d2-4b30-9281-ec362300d42b","name":"Image de fond","type":"image"},{"id":"3084d9ba-ab55-4e5a-931b-b9db3d09105f","name":"Article Content 1","type":"rich_text"},{"id":"0b77f83b-c31a-4889-b9b3-9a6d2e41fc86","name":"Author Bio","type":"rich_text"},{"id":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4","name":"Slug","type":"slug","role":"slug"},{"id":"df1c88d1-4bd8-4ecd-9059-463b9589de92","name":"Author Name","type":"plain_text"},{"id":"1f58afa6-2748-4188-b4a4-f1e54e37eca9","name":"Image 1","type":"image"},{"id":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383","name":"Title","type":"plain_text","role":"primary"},{"id":"8012fca9-4dbe-4d7c-993c-d37b30a37c6d","name":"Article Content 3","type":"rich_text"},{"id":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3","name":"Fav-image","type":"image"},{"id":"cc1e5ce2-ba49-43af-b78b-225562b85284","name":"Questions fréquentes","type":"rich_text"},{"id":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9","name":"Tag","type":"plain_text"},{"id":"b5be4125-5bdd-482f-8b12-191c8a4422f3","name":"À retenir","type":"rich_text"},{"id":"7b900d5c-96dc-41e2-be74-2a6610216543","name":"Date de publication","type":"plain_text"},{"id":"bc08dd34-58e3-4208-ad8c-a02df2239e1b","name":"Chapô","type":"rich_text"},{"id":"0a981f8a-7dbb-440d-a940-25d9060c9b11","name":"Author Job Title","type":"plain_text"},{"id":"054b5e89-1958-4bbe-907f-bda21bcc691d","name":"Article Content 2 / image","type":"rich_text"},{"id":"7b1ea3d0-62d9-49a8-b96e-f453f816f81e","name":"Article Content 4 / image","type":"rich_text"},{"id":"3885fcba-a6df-473a-8e7e-799777173a06","name":"Image 2","type":"image"}],"itemById":{"7c10a08b-d604-4d4d-a009-2400c53b6b59":{"id":"7c10a08b-d604-4d4d-a009-2400c53b6b59","index":"!","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"6918a194-ccf5-446a-9696-7ee76169ba54","value":"Guide pratique","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"0256a557-6df8-4761-989f-998f57f83be5","value":"David Francisque","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"ceea47ab-01b9-474b-8e4a-ff959851412c","value":"Maintenance et SAV d’un appareil onde de choc : le guide","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"589589f2-6968-4413-9855-8e124d5c36e5","value":"maintenance-appareil-onde-de-choc","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"fd9e9347-d916-49b9-a9df-655f938c95fb","value":"{\"image\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"imageThumbnail\":\"7d7136296b7a4d36dd8d48dba7011c9f29f082ea\",\"originalImageHeight\":240,\"originalImageWidth\":375,\"altText\":\"Photo d'un kit de révision\",\"fileName\":\"image 19.png\"}","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"e209398f-8921-4b09-b525-4ca98ae368f5","value":"23 septembre 2026","itemId":"7c10a08b-d604-4d4d-a009-2400c53b6b59","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"}]},"8e0217f5-7cdc-41f6-9db8-474dea263b83":{"id":"8e0217f5-7cdc-41f6-9db8-474dea263b83","index":"!O","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"fc81924b-1d3a-4dc8-9af8-d86e5de1f37f","value":"revision-piece-a-main-onde-de-choc","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"a6dc4f1c-71c5-4cd8-bfc5-e43857c2ca28","value":"Quand réviser la pièce à main d’un appareil onde de choc ?","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"c8c5b9fe-d69c-46a9-9bd6-ef89a18790b1","value":"David Francisque","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"bc5903f5-34d0-47a7-8937-03422d79e1c7","value":"Guide pratique","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"c5c84e77-acfd-4265-bfc0-955de5ec65e5","value":"{\"image\":\"5a6a7af39c577eb6cab53537d23bdca6b652c500\",\"imageThumbnail\":\"08fd98696723a3ddf925504168ddf4eacbee85c1\",\"originalImageHeight\":630,\"originalImageWidth\":1200,\"altText\":\"Nombre de choc possible sur un appareil médical par onde de choc\",\"fileName\":\"fav-quand-reviser-1200x630.png\"}","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"3c7927e3-e5b4-4037-9d32-4f6ec13b2d9f","value":"23 septembre 2026","itemId":"8e0217f5-7cdc-41f6-9db8-474dea263b83","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"}]},"96831a50-8ca8-4cca-bb18-8954cc156fb7":{"id":"96831a50-8ca8-4cca-bb18-8954cc156fb7","index":"!7","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"f280f385-0249-43c4-9bae-0f98efef4202","value":"Kit de révision Storz Medical : contenu, versions et montage","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"adf99d24-6e9e-4faf-84b7-05693a0dad50","value":"kit-revision-storz-medical","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"1730240e-1f3e-49c2-b3df-87a58b3f8c46","value":"David Francisque","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"152c803c-67cf-41bb-b0ba-5a91befa56b7","value":"23 septembre 2026","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"},{"id":"682524d3-f207-4b3a-9114-d267b2365633","value":"{\"image\":\"413c90202eefbf53f8adc18b78726fd4025e75e1\",\"imageThumbnail\":\"3c5de459399cc5edb94930127750757a6ebe2a29\",\"originalImageHeight\":1500,\"originalImageWidth\":1500,\"altText\":\"Kit de révision Storz Medical avec le projectile, le tube de guidage et les joints. \",\"fileName\":\"Kit de révision Storz medical.jpg\"}","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"4fcf599e-5537-4c9d-bee9-ae113f3be715","value":"Guide pratique","itemId":"96831a50-8ca8-4cca-bb18-8954cc156fb7","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"}]},"e678315e-a26e-4261-99f6-2576fbb7bc4e":{"id":"e678315e-a26e-4261-99f6-2576fbb7bc4e","index":"!f","collectionId":"d4a5b68c-8afd-4bbe-a7ac-e9a8422fedde","fields":[{"id":"d782a7f2-2a35-4c93-a7ef-97934946e141","value":"{\"root\":{\"children\":[{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"0b77f83b-c31a-4889-b9b3-9a6d2e41fc86"},{"id":"7adb5007-d326-409e-9fb4-04482e88f680","value":"panne-appareil-onde-de-choc","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"402ba26f-8f6d-4f5f-bf20-62e6549f4ad4"},{"id":"578a76f6-f5fb-4576-be11-06947a662dc3","value":"Panne d'appareil onde de choc : causes et solutions","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"f2ba59b9-49cc-4ec6-9416-bda99d4c8383"},{"id":"c871064a-a8f9-4dc4-b0d7-e684f2e84164","value":"Guide pratique","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"261a3829-bc3b-449a-b4d0-2eb1b59bb4b9"},{"id":"94e4d304-ded3-4c95-859f-57037f4a5d99","value":"David Francisque","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"df1c88d1-4bd8-4ecd-9059-463b9589de92"},{"id":"96292eed-d2c7-45f8-a17d-24ba1de581c2","value":"Dirigeant de S-Médical Conseil","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"0a981f8a-7dbb-440d-a940-25d9060c9b11"},{"id":"927993f4-8665-45ad-bf18-758cb09649bd","value":"29 octobre 2026","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"7b900d5c-96dc-41e2-be74-2a6610216543"},{"id":"abb628f0-be67-4832-bf21-d0ef086b5c16","value":"{\"root\":{\"children\":[{\"children\":[{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Perte de puissance\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" ou\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\" fréquence irrégulière\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : remplacez d'abord le kit de révision (340 € TTC).\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Si le problème persiste\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : la valve de pression, le compresseur ou la Stop Valve sont en cause, le SAV prend le relais.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Applicateur usé ou fissuré\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : à remplacer, sinon il use le kit de révision prématurément.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreurs 10, 11, 14 ou 17\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : notez le code et contactez le SAV.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":4},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Devis sous 48 h\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", transport aller-retour inclus, \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"réparation en 7 jours environ.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":5}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"textFormat\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"b5be4125-5bdd-482f-8b12-191c8a4422f3"},{"id":"c865ce7e-f21d-494d-afa5-a816766142c7","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"D'où vient une fuite d'air ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Symptôme :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" un sifflement ou un souffle d'air pendant l'utilisation.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Causes possibles,\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" selon le modèle de l'appareil :\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"le joint au niveau du raccord du câble de la pièce à main ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"la valve de pression ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"un défaut d'étanchéité du compresseur.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":3}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" repérez d'où vient l'air (raccord du câble, pièce à main ou module). Cette indication accélère le diagnostic.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand appeler le SAV :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" dans tous les cas.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"L'appareil ne s'allume pas : que faut il vérifier ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Symptôme :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" l'écran reste éteint et l'appareil ne démarre pas.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" vérifiez en premier lieu le fusible et le câble d'alimentation.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand appeler le SAV :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" si l'appareil ne démarre toujours pas après ces vérifications.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"054b5e89-1958-4bbe-907f-bda21bcc691d"},{"id":"7683dddd-d5af-42fa-acc7-2f2a7706856e","value":"{\"image\":\"fb768a9ff75728d8f380c3e714114f4f395cc7d5\",\"imageThumbnail\":\"225e3d4feda02270c83512ca6b2951d6c9fa1bb0\",\"originalImageHeight\":1360,\"originalImageWidth\":1156,\"altText\":\"Contrôle du raccord de la pièce à main d’un appareil à ondes de choc pour rechercher l’origine d’une panne.\",\"fileName\":\"Contrôle du raccord radial\"}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"1f58afa6-2748-4188-b4a4-f1e54e37eca9"},{"id":"29903df2-b6da-4355-9fd1-1e11bb135550","value":"{\"image\":\"c61ba0f18e4cc0001bd153b37462a3b0002c0dfb\",\"imageThumbnail\":\"13a3bd3f016ab5dd6746d6074dc786518ac25359\",\"originalImageHeight\":941,\"originalImageWidth\":1672,\"altText\":\"Révision d’une pièce à main d’appareil à ondes de choc avec son tube de guidage, son projectile et ses joints.\",\"fileName\":\"Révision d'un applicateur d'ondes de choc\"}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"b2aaf651-c4d2-4b30-9281-ec362300d42b"},{"id":"8516ec14-0ad4-4278-a332-4f13425464ee","value":"{\"image\":\"f824fa3992d12744707ba8b44c5f74dfe00227ec\",\"imageThumbnail\":\"0950d780438ba7acb4e531b12cd4a646f27d4890\",\"originalImageHeight\":1254,\"originalImageWidth\":1254,\"altText\":\"Inspection des traces d’usure sur l’embout métallique d’un applicateur d’ondes de choc.\",\"fileName\":\"Inspection de l’embout métallique radial\"}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"3677c54d-6ac1-4d8e-97ba-1fed0316cab3"},{"id":"a54e9ece-422c-43d4-93a8-724727e7db85","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":8,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Questions fréquentes\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"center\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"textFormat\":8,\"tag\":\"h2\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Puis-je continuer à utiliser un appareil qui présente l'un de ces signes ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Mieux vaut l'éviter\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\". Une puissance délivrée qui ne correspond plus aux réglages affichés fausse vos séances, et des pièces usées peuvent endommager la pièce à main elle-même. La réparation coûte alors bien plus qu'un kit de révision.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Combien coûte la réparation d'un appareil à ondes de choc ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Cela dépend de la panne et du mode de prise en charge\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\". Le kit de révision coûte 340 € TTC et un applicateur 390 €. Si vous envoyez l'appareil par transporteur, le devis est gratuit. Pour une intervention sur site, les frais de déplacement et de main-d'œuvre sont facturés, sur devis établi avant l'intervention.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Comment se passe une prise en charge par le SAV ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h3\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Contactez S-Médical Conseil \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"au\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\" 06 04 50 48 66 \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"ou via le \",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"formulaire de contact\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"internal-link\",\"version\":1,\"textFormat\":1,\"nodeId\":\"2:6135\",\"cmsTarget\":null},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : vous recevez un devis sous 48 h. Comptez environ 7 jours de réparation, transport aller-retour inclus, selon la panne et la disponibilité des pièces détachées. L'appareil vous revient avec un rapport d'intervention à joindre à votre registre de maintenance.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"cc1e5ce2-ba49-43af-b78b-225562b85284"},{"id":"f867cf75-3b72-4699-ba8c-bd63be07243f","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Perte de puissance\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"fréquence irrégulière\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"fuite d'air\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\", \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"code d'erreur\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : une panne d'appareil à ondes de choc peut venir de la pièce à main, du compresseur ou de l'électronique. \",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Pour une perte de puissance ou une fréquence irrégulière, commencez par remplacer le kit de révision de la pièce à main. \",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Si le problème persiste, ou pour toute autre panne, c'est au SAV de poser le diagnostic. \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Voici les 6 pannes possibles, leurs causes et la marche à suivre.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"bc08dd34-58e3-4208-ad8c-a02df2239e1b"},{"id":"cc80270f-2794-4f71-846f-6832c9b23600","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Pourquoi mon appareil perd-il en puissance ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Symptôme :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" à réglages identiques, les chocs sont moins efficaces ou moins ressentis par le patient.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Causes possibles :\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"le kit de révision usé (projectile, tube de guidage, joints) ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"la valve de pression située dans la pièce à main ;\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"le compresseur ou la Stop Valve, qui régule la pression dans le module.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"value\":3}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" commencez par remplacer le \",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"kit de révision Storz Medical\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noopener noreferrer nofollow\",\"target\":\"_blank\",\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/kit-revision-storz-medical\"},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\". C'est la cause la plus simple à écarter, surtout si le compteur approche 1 million de chocs depuis la \",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"dernière révision\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noopener noreferrer nofollow\",\"target\":\"_blank\",\"title\":null,\"url\":\"https://www.smedicalconseil.fr/blog/revision-piece-a-main-onde-de-choc\"},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\".\",\"type\":\"text\",\"version\":1},{\"type\":\"linebreak\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand appeler le SAV :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" si la perte de puissance persiste avec un kit neuf. La valve de pression ou le compresseur est alors en cause, et le SAV approfondit le diagnostic.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Pourquoi la fréquence des chocs est-elle irrégulière ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Symptôme :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" le bruit de percussion change, le rythme devient irrégulier, ou des chocs sont manqués.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Causes possibles :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" le kit de révision usé, ou la valve de pression située dans la pièce à main.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" remplacez le kit de révision.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand appeler le SAV :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" si l'irrégularité persiste après le remplacement du kit.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"3084d9ba-ab55-4e5a-931b-b9db3d09105f"},{"id":"a3bc2ccf-bca1-4521-a933-a02958bca10c","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Faut-il remplacer un applicateur usé ou fissuré ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Symptôme :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" l'applicateur, aussi appelé transmetteur (l'embout de contact R15, D20…), est fissuré, déformé ou usé.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Cause probable :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" l'usure normale, car le projectile le frappe à chaque choc.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" remplacez-le. Un applicateur usé ou fissuré entraîne une usure prématurée du kit de révision. Il ne fait pas partie du kit : \",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"S-Médical Conseil le fournit au prix de 390 € TTC l'unité.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Pour le commander :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" par téléphone au 06 04 50 48 66 ou via le formulaire \",\"type\":\"text\",\"version\":1},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Devis Express\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"link\",\"version\":1,\"rel\":\"noopener noreferrer nofollow\",\"target\":\"_blank\",\"title\":null,\"url\":\"https://www.smedicalconseil.fr/contact\"},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\".\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"7b1ea3d0-62d9-49a8-b96e-f453f816f81e"},{"id":"451895ca-47e4-4cd6-91fc-98fe06ac8751","value":"{\"root\":{\"children\":[{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Que signifie le code d'erreur affiché ?\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Les codes les plus courants dépendent de la gamme de l'appareil :\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreur 10 (gamme Elite Edition)\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : problème au niveau du bouton de la pièce à main.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreur 11 (gamme Elite Edition)\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : défaut possible de la carte mère du module ou du câble haute pression (HP). Elle s'affiche aussi si l'appareil est allumé sans pièce à main branchée.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreur 14 (gamme Ultra)\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : capteur de pression défectueux.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreur 17 (gamme Ultra T-TOP)\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : problème possible au niveau du bouton ou de la carte électronique.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":4}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"textFormat\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Ce que vous pouvez faire :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" en cas d'erreur 11, vérifiez d'abord que la pièce à main est bien branchée, puis redémarrez. Pour les autres codes, notez le code et la gamme de l'appareil, puis éteignez-le. N'ouvrez ni l'unité de contrôle ni le compresseur.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Quand appeler le SAV :\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" si l'erreur persiste. Indiquez-nous le code et la gamme de votre appareil.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":1,\"textStyle\":\"\"},{\"children\":[],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"paragraph\",\"version\":1,\"textFormat\":0,\"textStyle\":\"\"},{\"children\":[{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Les 6 pannes en un coup d'œil\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"heading\",\"version\":1,\"tag\":\"h2\"},{\"children\":[{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Perte de puissance\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : remplacez le kit de révision, puis contactez le SAV si ça persiste.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":1},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Fréquence irrégulière\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : remplacez le kit de révision, puis contactez le SAV si ça persiste.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":2},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Fuite d'air\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : contactez le SAV.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":3},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Applicateur usé ou fissuré\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : remplacez l'applicateur.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":4},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"Erreur 10, 11, 14 ou 17\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : vérifiez le branchement de la pièce à main (erreur 11), puis contactez le SAV.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":5},{\"children\":[{\"detail\":0,\"format\":1,\"mode\":\"normal\",\"style\":\"\",\"text\":\"L'appareil ne s'allume pas\",\"type\":\"text\",\"version\":1},{\"detail\":0,\"format\":0,\"mode\":\"normal\",\"style\":\"\",\"text\":\" : vérifiez le fusible et le câble d'alimentation, puis contactez le SAV.\",\"type\":\"text\",\"version\":1}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"listitem\",\"version\":1,\"textFormat\":1,\"value\":6}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"list\",\"version\":1,\"textFormat\":1,\"listType\":\"bullet\",\"start\":1,\"tag\":\"ul\"}],\"direction\":null,\"format\":\"\",\"indent\":0,\"type\":\"root\",\"version\":1,\"textFormat\":1}}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"8012fca9-4dbe-4d7c-993c-d37b30a37c6d"},{"id":"93a01592-466c-4241-a804-d4da4e5fc437","value":"{\"image\":\"8e7c9a1ffce1f7c0c4c69c6e0b6547ba413ae2b5\",\"imageThumbnail\":\"8e7c9a1ffce1f7c0c4c69c6e0b6547ba413ae2b5\",\"originalImageHeight\":660,\"originalImageWidth\":660,\"altText\":\"Embout métallique d’un applicateur d’ondes de choc radiales présentant une fissure et des traces d’usure.\",\"fileName\":\"image 25 (1) (1).jpg\"}","itemId":"e678315e-a26e-4261-99f6-2576fbb7bc4e","fieldSchemaId":"3885fcba-a6df-473a-8e7e-799777173a06"}]}}}},"slugByItemId":{"12124197-c3d3-4112-b64a-fee99a5f3c36":"onde-de-choc-radiale-ou-focale","7c10a08b-d604-4d4d-a009-2400c53b6b59":"maintenance-appareil-onde-de-choc","e678315e-a26e-4261-99f6-2576fbb7bc4e":"panne-appareil-onde-de-choc","8e0217f5-7cdc-41f6-9db8-474dea263b83":"revision-piece-a-main-onde-de-choc","96831a50-8ca8-4cca-bb18-8954cc156fb7":"kit-revision-storz-medical"}}